UPVC Well Casing, Screen and Riser Pipes Delivered to the Philippines for 300 m Deep Wells
On 1 October 2026, a 40HQ container loaded at Qingdao on 25 August was opened in Manila and unloaded: 880 lengths — 2,640 metres — of ASTM F480 Schedule 80 UPVC well casing, slotted screen casing and high-pressure riser pipe. The customer is a Philippine distributor supplying water-well drilling projects, and the pipe was specified for wells down to 300 m. Fourteen days after unloading, the same customer placed a repeat order for the same products, with several more specifications added.
Shipment quick facts
|
Res |
Detalium |
|
Locum destinatum |
Manila, Philippinae |
|
Clientem |
Pipe distributor supplying water-well drilling projects in the Philippines |
|
Applicatio |
Deep water wells, specified to 300 m depth |
|
Producta |
UPVC well casing, UPVC slotted screen casing, UPVC high-pressure riser pipe |
|
Norma |
ASTM F480, Schedule 80 |
|
Longitudo per partem |
3 m, threaded joints |
|
Quantitas |
880 pcs / 2,640 m |
|
Container |
1 × 40HQ, approx. 28 tonnes of pipe |
|
Onus |
Conveyor-belt loading; smaller diameters packed into the gaps between the large casing |
|
Onustatum |
Qingdao, 25 August 2026 |
|
Perductus |
Manila, 1 October 2026 |
|
Repeat order |
15 October 2026 — same products, additional specifications |
What the specification needed
This order was specified for deep-well work, with wells to 300 m. At that depth the pipe string does two different jobs, and both get harder than they do at 100 m.
The UPVC well casing — see the casing and screen range — has to hold the borehole open against earth pressure and the water pressure outside the pipe, without collapsing or ovalising. The riser, also called the pump column, has to carry the pump’s discharge to the surface and hold the weight of the pipe string and pump from its top joint.
Id est cur ordo in parietibus Schedule 80 factus est, non in parietibus leviorebus, quae saepe in puteis subtilibus utuntur. Latitudo scissurae in tegumento reticulato pro singulis projectis ex distributione magnitudinis granulorum aquiferi statuitur, et cum cliente ad tempus ordinis confirmatur.
Quid in vase erat
|
Productum |
OD × paries |
ID |
Longitudo |
QTY |
|
Tegumentum uPVC |
273.1 × 17.5 mm (10 in) |
238.1 mm |
3 m |
cC PCs |
|
Tegumentum uPVC |
219.2 × 14.5 mm (8 in) |
190.2 mm |
3 m |
cC PCs |
|
UPVC tegumentum reticulatum scissuratum |
273.1 × 17.5 mm (10 in) |
238.1 mm |
3 m |
60 Pcs |
|
UPVC tegumentum reticulatum scissuratum |
219.2 × 14.5 mm (8 in) |
190.2 mm |
3 m |
60 Pcs |
|
Tubus ascēnsorius uPVC |
40 × 5.5 mm (1¼ in) |
29.0 mm |
3 m |
120 pcs |
|
Tubus ascēnsorius uPVC |
48 × 5.5 mm (1½ in) |
37.0 mm |
3 m |
120 pcs |
|
Tubus ascēnsorius uPVC |
60 × 6.4 mm (2 in) |
47.2 mm |
3 m |
120 pcs |
|
Totale |
|
|
|
880 pcs / 2,640 m |
Tres familiae productorum, una fabrica, unus aggregatus tolerantiarum. Hoc magis valet quam sonat: tuba, schermum et ascensor omnia in eadem fabrica producuntur et filetis mensurantur, itaque personale in loco non miscet tolerantias tubarum et filetorum ex tribus suppeditatoribus.

Cur 300 m mutationem specificandi inducit
Tria res magis valent dum puteus profundior fit.
Spissitudo parietis. Resistentia ad collapsum pendet ab ratione spissitudinis parietis ad diametrum exterius, et crescit praeceps dum haec ratio augescit — fere cum cubo eius. Schema 80 est classis parietis crassioris in ASTM F480, quare est punctum initiale consuetum ubi catena diuturnam pressionem externam et installationem profundam sustinere debet. Tubus decempollicis in hoc ordine spissitudinem parietis 17.5 mm habet, octempollicis vero 14.5 mm. Classes leviores in puteis subtilioribus plene idoneae sunt.
Praesens ascensoris et tensio. Un riser est dimensionné à partir de la pompe, non pas à partir de la profondeur du trou. La pression nette qu’il supporte est la pression de refoulement de la pompe moins la pression de l’eau à l’extérieur du tube ; elle dépend donc de la hauteur manométrique à l’arrêt de la pompe, de sa profondeur d’installation, du niveau d’eau dans le puits, ainsi que des pertes de charge par frottement et des surpressions. L’épaisseur de paroi doit donc être choisie en fonction d’une classe de pression, et non d’une liste de prix. Les risers de 1¼ pouce et de 1½ pouce de cette commande ont une épaisseur de paroi de 5,5 mm ; celui de 2 pouces a 6,4 mm. Un riser suspendu supporte aussi le poids de toute la colonne et de la pompe depuis son raccord supérieur ; ainsi, pour une installation profonde, la résistance à la traction de ce raccord constitue également un critère de vérification de conception.
Nombre de raccords. À 3 m par longueur, une colonne de 300 m comporte 100 raccords. Chaque raccord représente un point potentiel de fuite et quelques minutes de temps de forage, donc la qualité des filetages et la constance dimensionnelle déterminent la rapidité d’assemblage du puits. Pour les puits profonds, c’est l’une des raisons pour lesquelles la classe Schedule 80 est généralement privilégiée par rapport aux classes plus légères ; ce compromis est abordé dans Series 8 vs Schedule 80: quae melior est pro constructione profundi putei .
Onus imponendum: cingulum convectans, omne interstitium utile
Onus impositum est die 25 Augusti per cingulum convectans quod continens allevabat, eadem methodo quae in praecedentibus expeditionibus BSX usitata est. Circiter 28 tonnae tuborum in unum continens 40HQ introierunt. Tubi decempollicares et octopullicares in diversis blocis congeruntur, et interstitia inter magnos diametros per minores tubos ascensus implentur potius quam per cartones solutos mittantur.

Haec electio impaquetionis onus firmum servavit, nullum spatium liberum ad fores relinquens. Etiam tubos protegit: onus quod non potest lateribus moveri neque filum ad parietem continens abraderi potest.
Ab inquisitione ad ordinem repetitum: quinque dies
|
Dies |
Milestone |
|
25 Maii 2026 |
Inquisitio a cliente accepta |
|
Iulius 2026 |
Specificatio et ordo confirmati |
|
25 Augusti 2026 |
Continens apud Qingdao oneratum |
|
1 Octobris 2026 |
Advenit Manilam, exoneratum est |
|
15 Octobris 2026 |
Ordo repetitus positus est |
Transitus a oneratione ad adventum Manilam XXXVII dies duravit. Ab prima quaestione ad tubos in Manilam exoneratos circiter quattuor mensibus absumptum est, productionem et navigationem maritimam includens — pars de qua emptores saepe interrogant. Ordo repetitus XIV diebus post exoneratum secutus est, infra quinque menses ab prima quaestione.
Inspectio antequam fores clauderentur
Tres inspectiones factae sunt antequam contener clauderetur.
Spissitudo parietis cum calibro rotativo in singulis partibus productionis mensurata est, non solum in prima parte — lectio calibri indicat utrum linea extrudendi in cursu longo deflexerit. Filamenta ad formam et initium inspecta sunt, quoniam stringa centum iuncturarum quemlibet defectum filamenti centuplificat. Numeri partium cum ordine lineam per lineam in omnibus septem columnis specificatarum comparati sunt.



Quid ordo repetitus reapse dicat
Cliens exoneravit in die 1 Octobris et iterum ordinavit in die 15 Octobris, emens eadem producta et addens plures alias specificatones.
Distributor assumit periculum stocki qui non venditur aut non congruit cum schematibus; ideo reordinatio est decisio commercialis, non tantum beneficium. Duabus hebdomadibus non sufficit tempus ad relationem constituendam; sed sufficit ad apertionem aliquot fasciculorum, inspectionem filorum et parietum, atque iudicium utrum materia sit ea quae ordinata est.
Pro prima ordinatione novae seriei productorum, hoc est clarissima referentia quam praebere possumus: non tantum catalogus, sed secunda ordinatio cum latiore varietate.

Quid hoc significat pro projectis bene in Philippinis
Philippine well programmes are often supplied through Manila and moved onward by road to the drilling site, so pipe length and load security matter as much as pressure class. Three-metre lengths travel on standard trucks without a low-bed trailer and can be handled by a small crew at the rig, which is why this order was supplied in 3 m lengths.
For a 300 m well the specification work is the same anywhere: match wall thickness to depth and formation, match slot width to grain size, and match riser pressure rating to pump head and setting depth. Get those three right and the pipe is unremarkable for the next few decades — which is the point.
Quaestiones Frequentes
What was shipped in this container?
880 pieces of ASTM F480 Schedule 80 UPVC pipe in 3 m threaded lengths: 400 pcs of casing (10 in and 8 in), 120 pcs of slotted screen casing in the same two diameters, and 360 pcs of high-pressure riser pipe in 1¼ in, 1½ in and 2 in. Total 2,640 metres, about 28 tonnes, in one 40HQ container.
Can UPVC casing be used in a 300 m well?
Yes, when the wall thickness is chosen for the depth and the string is installed correctly. This order used Schedule 80 pipe: 17.5 mm wall on the 10-inch casing and 14.5 mm on the 8-inch, to ASTM F480. At depth the limiting factors are collapse resistance and joint integrity, not the material itself, so the planned installation — casing kept filled with water, centralised in the hole, gravel-packed or grouted as the design requires — should be checked against the pipe’s collapse rating before ordering.
Why 3 m lengths instead of 6 m?
Shorter lengths are easier to truck to a remote site, easier to handle at the rig without a crane, and easier to store on a small yard. The cost is more joints: a 300 m string at 3 m is 100 joints against 50 at 6 m, so thread quality has to be consistent. Buyers who have a crane and good road access sometimes prefer 6 m.
What is the difference between casing, screen and riser?
Casing est tubus paries-solidus qui foramen perforatum aperit. Casing cum foraminibus, vel ‘slotted screen casing’, est idem tubus cum foraminibus machinaliter factis, positus contra aquiferum ut aqua intret dum formatio retinetur. Riser — quod etiam dicitur ‘pump column’ — est minor tubus ad altam pressionem qui aquam a pompa ad superficiem vehit.
Quomodo eligere latitudinem foraminis pro formatione ex sabulo et grava?
Latitudo foraminis determinatur a distributione magnitudinis granulorum formationis, non autem ex voluntate. Si latior est, bene effundit sabulum; si angustior est, influum restringit et obturat. Methodus explicatur in quomodo eligere latitudinem foraminis idoneam .
Quanto tempore ordo huiusmodi perficitur?
Circa quattuor menses ab inquisitione ad descensum tuborum in Manilam: 13 hebdomadae ab inquisitione ad onerationem, deinde 37 dies ab oneratione ad advenientiam. Tempus productionis pendet a diametris et spissitudinibus parietum; programma confirmatur in statu ordinis.
Potestne haec specificatio iterari?
Yes. The seven specification lines in this order are held on file, which is why the repeat order — with additional sizes — could be placed two weeks after unloading without re-engineering the string. To repeat or adapt it, request the same specification .
Requiescere Praebere
Send the well depth, borehole diameter, formation type, pump head and pump setting depth, and BSX will return a casing, screen and riser specification with pricing and lead time. Product data: PVC-U well casing and slotted screen pipe et UPVC high-pressure submersible pump pipe . System design: drilling engineering solutions .